LNK501PN Power Integrations IC SWIT OCP CV/CC HV 8DIP
Integraallülitused (IC-d)
Tootja number:
LNK501PN
Tootja:
Tootekategooria:
Kirjeldus:
IC SWIT OCP CV/CC HV 8DIP
RoHs olek:
Andmetabelid:
Juhtimisfunktsioonid :
-
Osa olek :
Not For New Designs
Paigaldustüüp :
Through Hole
Pakend/ümbris :
8-DIP (0.300", 7.62mm), 7 Leads
Pakendamine :
Tube
Pinge – käivitamine :
-
Pinge – rike :
700V
Pinge – toide (Vcc/Vdd) :
-
Sagedus – ümberlülitamine :
30kHz ~ 42kHz
seeria :
LinkSwitch®
Sisemised lülitid :
Yes
Tarnija seadmepakett :
DIP-8B
Töötemperatuur :
-40°C ~ 150°C (TJ)
Töötsükkel :
77%
Väljundi isoleerimine :
Isolated
Veakaitse :
Current Limiting, Open Loop, Over Temperature, Short Circuit
Võimsus (vatti) :
5.5W
Topoloogia :
Flyback
Laos
36,688
Ühiku hind:
Võtke meiega ühendust Pakkumine
LNK501PN Konkurentsivõimelised hinnad
ChipIcil on ainulaadne tarneallikas. Pakume oma klientidele LNK501PN konkurentsivõimelise hinnaga. Saate nautida meie parimat teenust, ostes ChipIc LNK501PN. Parima hinna saamiseks saidil LNK501PN võtke meiega ühendust.
Hinnapakkumise saamiseks klõpsake
LNK501PN Iseärasused
LNK501PN is produced by Power Integrations, belongs to DC-DC muundurid PMIC - AC, eraldiseisvad lülitid.
LNK501PN Toote üksikasjad
:
LNK501PN – DC-DC muundurid PMIC - AC, eraldiseisvad lülitid disainitud puhvervõimendid ja toodetud Power Integrations.
LNK501PN, mida pakub Power Integrations, saab osta CHIPMLCC-st.
Siit leiate erinevaid juhtivate tootjate elektroonilisi osi rahu.
CHIPMLCC LNK501PN on range kvaliteedikontrolliga ja nõuetele vastav kõike nõuetele.
CHIPMLCC-s näidatud fondi staatus on ainult viitamiseks.
Kui te ei leia otsitavat osa, võtke meiega ühendust lisateavet, näiteks varude arvu andmetabelis LNK501PN (PDF), hind LNK501PN, Pinout LNK501PN, manuaal LNK501PN Ja LNK501PN asenduslahendus.
LNK501PN, mida pakub Power Integrations, saab osta CHIPMLCC-st.
Siit leiate erinevaid juhtivate tootjate elektroonilisi osi rahu.
CHIPMLCC LNK501PN on range kvaliteedikontrolliga ja nõuetele vastav kõike nõuetele.
CHIPMLCC-s näidatud fondi staatus on ainult viitamiseks.
Kui te ei leia otsitavat osa, võtke meiega ühendust lisateavet, näiteks varude arvu andmetabelis LNK501PN (PDF), hind LNK501PN, Pinout LNK501PN, manuaal LNK501PN Ja LNK501PN asenduslahendus.
LNK501PN FAQ
:
1. What is the maximum operating temperature for LNK501PN?
The maximum operating temperature for LNK501PN is 125°C.
2. What is the typical input voltage range for LNK501PN?
The typical input voltage range for LNK501PN is 85VAC to 265VAC.
3. What is the maximum output power that LNK501PN can handle?
LNK501PN can handle a maximum output power of 7.5W.
4. Does LNK501PN have built-in over-temperature protection?
Yes, LNK501PN is equipped with built-in over-temperature protection.
5. What is the typical efficiency of LNK501PN?
The typical efficiency of LNK501PN is around 85%.
6. Can LNK501PN operate in a continuous conduction mode (CCM)?
Yes, LNK501PN can operate in a continuous conduction mode.
7. What is the maximum frequency jitter range for LNK501PN?
The maximum frequency jitter range for LNK501PN is ±10%.
8. Is LNK501PN compliant with safety standards such as EN61000 and EN55022?
Yes, LNK501PN is compliant with safety standards including EN61000 and EN55022.
9. What is the typical start-up time for LNK501PN?
The typical start-up time for LNK501PN is less than 0.5 seconds.
10. Does LNK501PN require an external heat sink for thermal management?
No, LNK501PN does not require an external heat sink for thermal management.
The maximum operating temperature for LNK501PN is 125°C.
2. What is the typical input voltage range for LNK501PN?
The typical input voltage range for LNK501PN is 85VAC to 265VAC.
3. What is the maximum output power that LNK501PN can handle?
LNK501PN can handle a maximum output power of 7.5W.
4. Does LNK501PN have built-in over-temperature protection?
Yes, LNK501PN is equipped with built-in over-temperature protection.
5. What is the typical efficiency of LNK501PN?
The typical efficiency of LNK501PN is around 85%.
6. Can LNK501PN operate in a continuous conduction mode (CCM)?
Yes, LNK501PN can operate in a continuous conduction mode.
7. What is the maximum frequency jitter range for LNK501PN?
The maximum frequency jitter range for LNK501PN is ±10%.
8. Is LNK501PN compliant with safety standards such as EN61000 and EN55022?
Yes, LNK501PN is compliant with safety standards including EN61000 and EN55022.
9. What is the typical start-up time for LNK501PN?
The typical start-up time for LNK501PN is less than 0.5 seconds.
10. Does LNK501PN require an external heat sink for thermal management?
No, LNK501PN does not require an external heat sink for thermal management.
LNK501PN Seotud märksõnad
:
LNK501PN Hind
LNK501PN Maalimine
LNK501PN Tihvtide pinge
Pakkumised: Kiire hinnapakkumise kontroll
Minimaalne tellimus: 1
Sisaldab "LNK5" seeria tooteid